Annotation of wikisrc/tutorials/how_to_check_the_smart_status_of_your_harddisk.mdwn, revision 1.2
1.2 ! schmonz 1: # atactl
! 2:
! 3: S.M.A.R.T. is a monitoring tool for hard disks. With NetBSD you can show the smart values using following command:
! 4:
! 5:
! 6: # atactl wd0 smart status
! 7: SMART supported, SMART enabled
! 8: id value thresh crit collect reliability description raw
! 9: 1 100 0 no online positive Raw read error rate 2446
! 10: 4 98 0 no online positive Start/stop count 2492
! 11: 5 253 9 yes online positive Reallocated sector count 0
! 12: 7 253 51 yes online positive Seek error rate 0
! 13: 8 253 0 no offline positive Seek time performance 0
! 14: 9 99 0 no online positive Power-on hours count 1112403
! 15: 12 99 0 no online positive Device power cycle count 1418
! 16: 194 161 0 no online positive Temperature 53 Lifetime max/min 0/0
! 17: 197 253 9 yes online positive Current pending sector 0
! 18: 198 253 9 yes offline positive Offline uncorrectable 0
! 19: 199 100 0 no online positive Ultra DMA CRC error count 0
! 20: 200 100 51 yes online positive Write error rate 0
! 21: 201 100 51 yes online positive Soft read error rate 0
! 22:
! 23:
! 24: # smartctl
! 25:
! 26: Another utility to monitor hard disks is smartctl. This utility is part of the sysutils/smartmontools package.
! 27:
! 28:
! 29: # cd /usr/pkgsrc/sysutils/smartmontools/
! 30: # make package
! 31:
! 32:
! 33: With smartctl you can show the smart values using following command:
! 34:
! 35:
! 36: # smartctl -s on /dev/sd0d
! 37: smartctl version 5.36 [i386--netbsdelf] Copyright (C) 2002-6 Bruce Allen
! 38: Home page is http://smartmontools.sourceforge.net/
! 39:
! 40: Informational Exceptions (SMART) enabled
! 41: Temperature warning enabled
! 42:
! 43: # smartctl -a /dev/sd0d
! 44: smartctl version 5.36 [i386--netbsdelf] Copyright (C) 2002-6 Bruce Allen
! 45: Home page is http://smartmontools.sourceforge.net/
! 46:
! 47: Device: MAXTOR ATLAS10K5_300WLS Version: HPM7
! 48: Serial number: J8033RSK
! 49: Device type: disk
! 50: Transport protocol: Parallel SCSI (SPI-4)
! 51: Local Time is: Sun Nov 18 19:39:10 2007 CET
! 52: Device supports SMART and is Enabled
! 53: Temperature Warning Enabled
! 54: SMART Health Status: OK
! 55:
! 56: Current Drive Temperature: 47 C
! 57: Manufactured in week 05 of year
! 58: Current start stop count: 1074003968 times
! 59: Recommended maximum start stop count: 1124401151 times
! 60: Elements in grown defect list: 0
! 61:
! 62: Error counter log:
! 63: Errors Corrected by Total Correction Gigabytes Total
! 64: ECC rereads/ errors algorithm processed uncorrected
! 65: fast | delayed rewrites corrected invocations [10^9 bytes] errors
! 66: read: 0 0 0 0 0 0.000 0
! 67: write: 0 0 0 0 0 0.000 0
! 68:
! 69: Non-medium error count: 1115
! 70:
! 71: Last n error events log page
! 72: No self-tests have been logged
! 73: Long (extended) Self Test duration: 5760 seconds [96.0 minutes]
! 74:
! 75:
! 76: # smartd
! 77:
! 78: Smartd is a SMART Disk Monitoring Daemon (part of the smartmontools).
! 79:
! 80: